Welcome

TCP/IP Package For RT-11 Documentation

-... Hardware Installation


Q-BUS Systems

   A  Q-Bus  based  RT-11  system requires the installation of a
DEQNA or DELQA communications controller.  A system memory of at
least  512k  is  required  when installing the Internet Package.
The DEQNA/DELQA EQ22XM.SYS handler requires 36k bytes  for  code
and  packet  buffers  (the NQXV56.SYS handler requires 14K bytes
for code and packet buffers)  and  the  network  server  program
TCPIP.SAV will use 64k bytes for a maximum of approximately 100k
bytes before activating any client/server programs.  Each active
client/server  program will use an additional 64k bytes plus one
or two global PLAS regions each 8k bytes in size.  


                              NOTE

     It is possible to install the TCP/IP Package on a 248K
     machine  using  the  DEQNA/DELQA   18-bit   EQ18XM.SYS
     handler.   This  handler  requires 7.5k bytes for code
     and packet buffers.  This configuration allows at most
     one networking application to be active.  



   Blockmode  memory is recommended for use with the DEQNA/DELQA
communications controller although not necessary.  The DEQNA  or
DELQA interface is connected via a bulkhead cable assembly (with
perhaps an extension ETHERNET  transceiver  cable)  to  a  tran-
sceiver (with either a thick or thin wire connection).  

=> Section Index

UNIBUS Systems

   A  Unibus  based  RT-11 system requires the installation of a
DEUNA or DELUA communications controller.  A system memory of at
least  384k is recommended when installing the Internet Package.
The DEUNA/DELUA 22-bit (Unibus Mapping) NUXV56.SYS  handler  re-
quires  14k  bytes  for  code and packet buffers and the network
server program TCPIP.SAV will use 64k bytes  for  a  maximum  of
approximately 78k bytes before activating any client/server pro-
grams.  Each active client/server program will use an additional
64k  bytes  plus one or two global PLAS regions each 8k bytes in
size.  


                              NOTE

     It is possible to install the TCP/IP Package on a 248K
     machine using the DEUNA/DELUA 18-bit (Non Unibus  Map-
     ping)  EU18XM.SYS handler.  This handler requires 7.5k
     bytes for code and packet buffers.  This configuration
     allows  at  most  one networking application to be ac-
     tive.  



   The  DEUNA or DELUA interface is connected via a bulkhead ca-
ble assembly (with perhaps an extension ETHERNET transceiver ca-
ble)  to  a  transceiver  (with  either  a  thick  or  thin wire
connection).  

=> Section Index

Serial Port Installation

   If  the  system  is  to be configured for remote Telnet login
then a pair of dedicated serial lines is required for  the  ses-
sion.   The  dedicated  pair  consists  of a multi-terminal line
cross connected to second multi-terminal line via  a  NULL-MODEM
cable.  

   For a DLV11-J four port serial board the cross connection may
be easily obtained by constructing a 4" cable with the  10  wire
flat  cable  flipped  between  the  two  ends (1->10, 2->9, ....
10->1).  Then cut wires 1,2,9,and 10 at both connectors  leaving
a 6-wire NULL-MODEM cable.  The DLV11-J baud rate should be lim-
ited to 4800 as two serial ports are required  for  the  session
and is a relatively heavy burden even for a LSI-11/73.  

   Cross  connected  DZ ports will provide faster and more effi-
cient communication.  

=> Section Index

... Exit TCP/IP Documentation

... Home Page

Last Updated: June 2008